Descripción del producto
The leakage probes of the type series ELH are approved by the "DIBt" for the monitoring of collecting chambers, collecting devices, inspection and filling shafts.
Datos técnicos
Datos generales
- Clase de protección
- IP 68
- Material del cuerpo de la sonda
- PE, PVC, PPH, PVDF
- Diámetro cuerpo sonda
- 15 mm, 25 mm, 40 mm
- Temperatura de funcionamiento
- atmosphärisch
- Presión de funcionamiento
- atmosphärisch
- Valor de resistencia de la monitorización en línea
- 22 kΩ / 100 kΩ
Material
- Conexión roscada
- PVDF
- Cable
- TPK ( PVC Basis)
- a petición
- FEP (Teflon), PVC - blau
- Longitud del cable
- auf Wunsch (Standard 3 m)
- Material de las varillas del sensor
- Edelstahl (1.4571), Hastelloy B, Hastelloy C, Titan, Tantal, Glas-Kohlestifte
Más información del producto
The screw connection of the ELH is made of PVC, the probe body of the ELH is made of the materials PE, PPH, PVC or PVDF, depending on the requirements. The electrode tips are made of stainless steel 1.4571, Hastelloy B, Hastelloy C, titanium, tantalum or glass-carbon pins. This makes the ELH suitable for use with highly aggressive media. The cable length can be adjusted at the screw connection of the ELH .
The electrode relays ER-107..., ER-217... or ER-145... (intrinsically safe control circuit) supply a measuring voltage which causes an operating current to flow through the signal line via the resistor installed in the conductive electrode. If the conductive medium rises to the level of the electrode tips of the level detector, a circuit is closed. This causes the potential-free output contacts on the electrode relay to switch over.
In order to cope with the different conductivities of the liquids, the electrode relays ER-107..., ER-217... or ER-145... can be supplied in two different response ranges (1...30 kΩ / 6...90 kΩ). Within these ranges, the response value can be adjusted by means of a potentiometer.
If there is a line interruption, the output contacts are switched over (as in the case of an alarm caused by reaching the response level or voltage failure). If a line short-circuit occurs, this corresponds to an "alarm message" (as in the case of reaching the response level). The electrode relay operates according to the closed-circuit current principle, i.e. in the event of a power failure, the output contacts switch in the same way as when the response level is reached.
If there is a line interruption, the output contacts are switched over (as in the case of an alarm caused by reaching the response level or voltage failure). If a line short-circuit occurs, this corresponds to an "alarm message" (as in the case of reaching the response level). The electrode relay operates according to the closed-circuit current principle, i.e. in the event of a power failure, the output contacts switch in the same way as when the response level is reached.
- High chemical resistance
- Problem-free, variable installation in the collection tray due to "rope design
- Various diameters 40 mm, 25 mm and 15 mm.
- Low response height
- Use in Ex-Zone 1 (Category 2) with ER-145...
- Line monitoring for cable short circuit / cable breakage
System structure
The leakage detection system consists of the ELH and the electrode relays ER-107, ER-217 or ER-145. The leakage detection system can be connected to our "Optical Acoustic Alarms" type OAA-300.
Documentos y descargas
Instrucciones de ajuste
Instrucciones de instalación y funcionamiento
Certificado de prueba
Declaración de conformidad
Productos de esta serie
2 Las variantes serán mostradas
Accesorios
OAA-300
Ir al producto