Description
The leakage probes of the type series ELH are approved by the "DIBt" for the monitoring of collecting chambers, collecting devices, inspection and filling shafts.
Technical Data
General data
- Protection class
- IP 68
- Probe body material
- PE, PVC, PPH, PVDF
- Diameter probe body
- 15 mm, 25 mm, 40 mm
- Operating temperature
- atmosphärisch
- Operating pressure
- atmosphärisch
- Resistance value of line monitoring
- 22 kΩ / 100 kΩ
Material
- Screw connection
- PVDF
- Cable
- TPK ( PVC Basis)
- on request
- FEP (Teflon), PVC - blau
- cable length
- auf Wunsch (Standard 3 m)
- Material Sensor rods
- Edelstahl (1.4571), Hastelloy B, Hastelloy C, Titan, Tantal, Glas-Kohlestifte
Further product information
The screw connection of the ELH is made of PVC, the probe body of the ELH is made of the materials PE, PPH, PVC or PVDF, depending on the requirements. The electrode tips are made of stainless steel 1.4571, Hastelloy B, Hastelloy C, titanium, tantalum or glass-carbon pins. This makes the ELH suitable for use with highly aggressive media. The cable length can be adjusted at the screw connection of the ELH .
The electrode relays ER-107..., ER-217... or ER-145... (intrinsically safe control circuit) supply a measuring voltage which causes an operating current to flow through the signal line via the resistor installed in the conductive electrode. If the conductive medium rises to the level of the electrode tips of the level detector, a circuit is closed. This causes the potential-free output contacts on the electrode relay to switch over.
In order to cope with the different conductivities of the liquids, the electrode relays ER-107..., ER-217... or ER-145... can be supplied in two different response ranges (1...30 kΩ / 6...90 kΩ). Within these ranges, the response value can be adjusted by means of a potentiometer.
If there is a line interruption, the output contacts are switched over (as in the case of an alarm caused by reaching the response level or voltage failure). If a line short-circuit occurs, this corresponds to an "alarm message" (as in the case of reaching the response level). The electrode relay operates according to the closed-circuit current principle, i.e. in the event of a power failure, the output contacts switch in the same way as when the response level is reached.
If there is a line interruption, the output contacts are switched over (as in the case of an alarm caused by reaching the response level or voltage failure). If a line short-circuit occurs, this corresponds to an "alarm message" (as in the case of reaching the response level). The electrode relay operates according to the closed-circuit current principle, i.e. in the event of a power failure, the output contacts switch in the same way as when the response level is reached.
- High chemical resistance
- Problem-free, variable installation in the collection tray due to "rope design
- Various diameters 40 mm, 25 mm and 15 mm.
- Low response height
- Use in Ex-Zone 1 (Category 2) with ER-145...
- Line monitoring for cable short circuit / cable breakage
System structure
The leakage detection system consists of the ELH and the electrode relays ER-107, ER-217 or ER-145. The leakage detection system can be connected to our "Optical Acoustic Alarms" type OAA-300.
Documents and Downloads
Settings instructions
Mounting and installation instructions
declaration of conformity
products in this series
2 variants are displayed
Accessoires
OAA-300
go to product