Description
The conductive electrodes of the EE-21/EE-22 series enable the monitoring of conductive liquids within the Ex area Zone 0 (Cat. 1).
Données techniques
Variants
- cable connection on side
- EE-21
- cable connection on top
- EE-22
Propriétés
- raccordement
- Edelstahl (1.4571)
- Classe de protection EN60529
- IP65
- Protection Ex
- TÜV 02 ATEX 1796 X
- Type de protection Ex
- II 1 G Ex ia IIC T6 bzw. Ex ia IIB T6 / II ½ G Ex ia IIC T6 bzw. Ex ia IIB T6
- filetage de raccordement
- G1" | G1¼"
- Entrée de câble EE-21
- Edelstahl (1.4571)
- Entrée de câble EE-22
- Kunststoff
- Diamètre de la tige
- 4 mm | 6 mm
- Longueur de la tige
- max. 6.000 mm
- Pression de fonctionnement côté média
- max. 40 bar
- Entretoise
- ab Länge > 1000 mm je 1 pro 1000 mm
Matériau
- electrode body
- Edelstahl (1.4571)
- Joint (tête)
- Viton
- Joint (côté support)
- Viton | PTFE
- Potential equalisation conductor connection
- Edelstahl (1.4571)
- electrode rods
- Edelstahl (1.4571) | Hastelloy C | Tantal
- Coating
- PTFE
Température de fonctionnement
- Category 1 Class T6...T1
- 60 °C
- Category 2 Class T6
- 80 °C
- Category 2 Class T5
- 95 °C
- Category 2 Class T4
- 130 °C (100°C)
- Category 2 Class T3...T1
- 150 °C (100°C)
EE-2X configuration
EE2 | 1 | - | 2 | - | 3 | - | 4 | - | 5 | - | 6 | - | 7 | - | 8 |
Autres informations sur les produits
The conductive electrodes of the EE-21/EE-22 series are intended for installation inside containers whose gas space inside the container may be classified as Ex Zone 0 (Cat. 1).
- EC type examination certificate TÜV 02 ATEX 1796 X
- can be used entirely within category 1 (Ex zone 0)
- Also with cable tail
- Up to 4 limit levels can be detected with one electrode
- G 1" thread connection possible (for one limit level)
- Limit level detection of conductive gaseous media (ammonia water, fermentation/digestion solutions)
- Interference-free measurement
- Boundary layer measurement conductive / non-conductive
- The conductive electrodes EE-21/EE-22 can be used in conjunction with our Ex electrode relays of the ER-14... series.
The type EE-21 for cat. 1 is to be installed in conjunction with the flame-proof cable feedthrough FK-100.
If the conductive electrodes are installed on containers that must be protected against ignition hazards caused by lightning in accordance with TRbF 20 section / chapter 12, then The requirements of TRbF 20 Section/Chapter 12 must be observed during installation.