TRM-100

Turbidimeter (0...1.000 FNU or 500...4.000 FAU)

Características

4...20 mA

Familia de productos

Analítica de procesos

Clase de producto

Turbidez

Adecuado para

Líquido

Principio de medición

optical


Características importantes

  • Measurement of "turbidity" is carried out using the scattered light and transmitted light method

  • The turbidimeter works as a stand-alone system.

  • Continuous turbidity measurement with 1 freely adjustable changeover contact

Descripción del producto

The turbidimeter TRM-100 is a compact device for measuring turbidity in liquids. The "turbidity" is measured using the scattered light method (angle 90 degrees) for the turbidity range of < 1,000 FNU (Formazine Nephelometric Units) and the transmitted light method (angle 0 degrees) for the turbidity ranges > 1,000 FAU (Formazine Attenuation Units).

Datos técnicos

Propiedades
Presión de funcionamiento
max. 10 bar @ 20 °C | max. 2,5 bar @ 60 °C
Rango de medición
500...4.000 FNU / FAU
Precisión de medición
+/-5 %
Posición de montaje
horizontal
Conexión de proceso
DN 20 | DN 40
Conexión por brida
>= DN 20
Número de emisores
2
Número de receptores
1
Material
Sello
EPDM | optional FPM (Viton)
Conexión de proceso
PVC | PPH
Tubo de medición
Borsilikatglas mit Nano Beschichtung
Entrada
Fuente de alimentación
18...30 V DC
Consumo eléctrico
< 2 W
Salidas
Contacto de salida
4...20 mA
Retardo de conmutación (ajustable)
1...10 s
Clase de protección
IP 65
Voltaje de conmutación
max. 250 V AC | max. 115 V DC
Corriente de conmutación
max. 3 A
Capacidad de conmutación
max. 500 VA, 60 Watt
Contacto conmutado libre de potencial
1 @ 1...10 s

TRM-100 Configurar

Su configuración

Designación básica
TRM-100
Material
Measuringrange
Connection
Flange
Sealing

Más información del producto

The turbidimeter TRM-100 is a compact device for measuring turbidity in liquids. The "turbidity" is measured using the scattered light method (angle 90 degrees) for the turbidity range of < 1,000 FNU (Formazine Nephelometric Units) and the transmitted light method (angle 0 degrees) for the turbidity ranges > 1,000 FAU (Formazine Attenuation Units).

  • Continuous turbidity measurement
  • Output 4...20 mA
  • Plastic version PVC and PPH
  • Use without additional transmitter
  • 2 infrared transmitters and 1 infrared receiver (IR scattered light/transmitted light 860 nm)
  • FNU/FAU Display 4 digits
  • 1 changeover contact freely adjustable Work / Quiescent current

Documentos y descargas

Benefíciese de nuestros productos

Reparación y mantenimiento

Reparación y mantenimiento

Fabricamos productos duraderos y de alta calidad. No obstante, si fuera necesario un mantenimiento, estamos a su disposición en nuestro centro de servicio.

Desarrollo de proyectos

Desarrollo de proyectos

¿Aún no le convencen del todo nuestros productos estándar? Le ofrecemos la posibilidad de personalizarlos en función de sus deseos. ¡Póngase en contacto con nosotros!

Asesoramiento sobre aplicaciones

Asesoramiento sobre aplicaciones

¿Busca un producto adecuado para su tarea de medición? Le recomendaremos un producto de nuestra gama que se ajuste a sus especificaciones.

Asesoramiento sobre aplicaciones

Asistencia y puesta en marcha

¡Asistencia rápida y sin complicaciones cuando las cosas se complican! Nuestro equipo de asistencia está a su disposición para responder a cualquier pregunta sobre la puesta en marcha.

¡Nuestros ingenieros de aplicaciones le asesoran personal, completa y profesionalmente!

¡Póngase en contacto con nosotros por teléfono o por escrito!

¡Llámenos ahora!

+49-6251-8462-0

Formulario de contacto

Logo of Fluid.iO Sensor + Control

Fluid.iO
Sensor + Control
GmbH & Co. KG

An der Hartbrücke 6
64625 Bensheim
Tel.: +49-6251-8462-0
E-Mail: info@fluidio.de