ER-214

Electrode Relays

Features

2-Kanal

product family

Alarm

product class

Relais

suitable for

fluids

measurement principle

Special characteristics

  • Adjustable sensitivity

  • Various supply voltages & switching delays

  • Based on microprocessor technology

Description

Electrode relays for conductive level detection for all areas in which conductive, liquid media are to be detected, controlled or monitored

Technical Data

Properties
Protection class EN60529 clamp
IP 20
Protection class EN60529 front panel housing
IP 40
Operating temperature
–20...+60 °C
Storage temperature
–30...+80 °C
AC nominal frequency
48...62 Hz
Power consumption
max. 1 W / VA
Weight
ca. 150 g
Input
Open circuit voltage
≤ 10 V AC
Short-circuit current
≤ 5 mA
Output
Contacts
1 potentialfreie Wechselkontakte pro Kanal
Switching voltage
min. 5 V | max. 250 V AC | max. 150 V DC
Switching current
min. 5 mA | max. cosφ=1 3A | max. cosφ=0,7 1 A/AC | max. cosφ=1
Switching capacity
min. 300 mW | max. 750 VA / 150 W (30 V DC / 5 A) / 18 W (150 V DC / 0,12 A)
Working / Idle current
umschaltbar
overvoltage category
EN 61010-1 Kategorie III

ER-214 configuration

ER-214 1 - 2 - 3 - 4 - 5 - 6

1 Gehäuse

  • B : Steckklemme (verschraubbar)
  • C : Steckklemme (Federkraft)
  • K : 19" Kartenausführung
  • BC : 35mm Tragschiene

2 Ausgang

  • 1 : 1 Wechsler

3 Schaltverzögerung

  • 0 : fest ca. 0,5 s
  • 1 : fest ca. 2 s
  • 2 : fest ca. 4 s
  • 3 : 0,5...10 s in 4 Stufen

4 Empfindlichkeitsbereich

  • 1 : 2...300 kΩ
  • 2 : 10...1000 kΩ
  • 3 : 0,2...3 kΩ

5 Versorgungsspannung

  • 0 : 24 V DC
  • 1 : 24 V AC
  • 2 : 42 V AC
  • 3 : 48 V AC
  • 5 : 127 V AC
  • 6 : 230 V AC
  • 7 : 240 V AC
  • 8 : 115 V AC

6 Quittiertaster

  • L : mit Taster „Max“
  • V : mit Taster „Min“

Further product information

  • Operating current, closed-circuit current switchable
  • Reliable galvanic isolation between input, network and contacts
  • Adjustable sensitivity ranges
  • Various supply voltages
  • Various switching delays (also adjustable)
  • Acknowledge switch optional
  • 1 and 2 channel relays, 2-channel relay measures 2 limit values or 2 MinMax and 1 limit value
  • 19” board version
  • TÜV ATEX tested (ER-142… and ER-143…)
  • ER-214 is based on microprocessor technology

Documents and Downloads

Our application engineers advise you personally, comprehensively and professionally!

Simply contact us by phone or e-mail!

Call us right away!

+49-6251-8462-0

contact form

Logo of Fluid.iO Sensor + Control

Fluid.iO
Sensor + Control
GmbH & Co. KG

An der Hartbrücke 6
64625 Bensheim
Tel.: +49-6251-8462-0
E-Mail: info@fluidio.de