Description
TÜV-certified, type-tested electronic safety switching device (SIL2)
Technical Data
Properties
- Operating voltage
- 16...32 V DC (max. 5,9 W)
- Dimensions
- 150 x 60 x 42 mm (L x B x H)
- Housing
- Aluminium (eloxiert)
- Protection class
- IP65
Approvals
- DGRL 2014/68/EU Kat:IV
- Baumustergeprüft gemäß Druckgeräterichtlinie
- DIN EN12263:1998
- Kälteanlagen und Wärmepumpen Sicherheitsschalteinrichtungen zur Druckbegrenzung -Anforderungen und Prüfungen; Kategorie IV
- DIN EN378:2020
- Kälteanlagen und Wärmepumpen - Sicherheitstechnische und umweltrelevante Anforderungen
- DIN EN61508:2011
- SIL2
Measuring ranges
- Measuring range relative pressure (nominal pressure)
- -1…500 bar
- Measuring range differential pressure (nominal pressure)
- 0…1 mbar - 0…1.000 mbar
- Setting accuracy (from nominal pressure)
- 0,1 %
Operating conditions
- Pressure type
- Relativdruck, Differenzdruck
- Temperature of the fluid
- -40…+125 °C
- Ambient temperature
- -20…+65 °C
- Parts in contact with media
- Edelstahl
process connection
- Version relative pressure
- G ¼“ Innengewinde
- Version differential pressure
- G ⅛“ Innengewinde
- Adapter for process connection
- 6mm; 8mm oder 10mm
electrical connection
- Analogue current output
- 1x 4…20 mA
- Digital inputs/outputs
- 2x Alarm oder 1x Alarm & 1x Fernentriegelung
Load capacity of the switching contacts DC (24V)
- DC1
- 16 A
- DC13
- 1,5A
Load capacity of the switching contacts AC (230V)
- AC1
- 16 A
- AC3
- 10 A
- AC15
- 7 A
ES-Serie configuration
Your Configuration
- Basename
- ES-2
- Measurend
- Safetyfunction
- Direction
- measuring-range
Further product information
The devices of the ES-2x series are electronic safety switching devices for pressure monitoring with comprehensive self-diagnostic functions and fail-safe design. The devices are used as pressure regulators, for minimum or maximum pressure limitation on compressors in refrigeration and air conditioning systems, on heat pumps, steam boiler systems and on hydraulic systems. With the exception of the integrated switching relays, there are no mechanically moving components, resulting in high vibration resistance and a long service life. The switching limits can be conveniently set and precisely monitored. Comprehensive self-diagnostic and logging functions ensure safe monitoring and fast shutdown of the source of danger as well as high traceability of events that have occurred.
Documents and Downloads
General information
Quick Start Guide
Mounting and installation instructions
declaration of conformity
products in this series
4 variants are displayed
Video of the product
Accessoires
Smart Pressostat
go to productSimilar Products
ZT-S
Functionally safe pressure transmitter for ES series
go to product